Heating, Cooling, And Plumbing Repair Services In Menomonee Falls, Wisconsin

Heating, Cooling, and Plumbing Repair Services in Menomonee Falls, Wisconsin

Your Local Heating and Cooling Experts since 1929

Our team of professionals are available to provide superior heating, HVAC, and air conditioning services for homes and commercial properties in Menomonee Falls, Wisconsin. Our number one priority is customer satisfaction, and we go above and beyond to ensure you receive the best service possible.

With our team of Nate-certified technicians and friendly office staff, we are dedicated to delivering exceptional results. We understand the importance of a comfortable home or workplace, and that is why we are committed to providing reliable heating and cooling solutions all year round.

For HVAC services in Menomonee Falls, look no further than The Thielmann Group. Contact us online or call (262) 299-6197 to get started.

Menomonee Falls Heating and Air Conditioning Company

Looking for reliable heating and cooling services in Menomonee Falls? Look no further than our team! With a strong reputation since 1929, our expert staff ensures top-notch equipment installation and repair. We take pride in offering the best heating products, installation, and services in Waukesha County.

We offer various types of heating and HVAC options, including:

Our factory-trained and NATE-certified professionals are ready to get the job done right. Rest assured, we’ve got you covered with prompt furnace repair services in case of any heating problems. Our NATE-certified specialists are available 24/7 to service and repair all makes and models. Stay warm during harsh Wisconsin winters – reach out to us for all your heating or furnace repair needs in Menomonee Falls, WI.

Thielmann - New Berlin - Install Truck 24

Air Conditioner Repair and Installation Services

Looking for a new air conditioning system? Look no further! We have the perfect solution to keep you cool and suit your budget. Our experienced team will ensure a flawless installation, perfectly sized to your space. Our technicians are factory trained and NATE-certified, equipped with years of knowledge to install your new central air or ductless system with superior workmanship. Stay cool with confidence!

We work on all types of cooling systems, including:

  • Air conditioners: We can work on all models of air conditioning systems for residential and commercial properties.
  • Heat pumps: We can repair, replace, or maintain energy-efficient heat pumps that deliver warm air inside and outside the home.
  • Ductless mini-splits: We can service ductless HVAC units that provide total climate control for single rooms.

Duct Cleaning

The ductwork in your HVAC system plays a vital role, acting as the lungs of your home. Every bit of heated or cooled air flows through it, ensuring comfort and well-being. At The Thielmann Group we take pride in ensuring clean and healthy indoor environments for homes and businesses.

From humidity control and air purification to duct cleaning and more, we offer solutions to improve your indoor air quality. The ductwork in your HVAC system plays a vital role, acting as the lungs of your home. Every bit of heated or cooled air flows through it, ensuring comfort and well-being.

  • Air purifiers
  • Humidifiers
  • Dehumidifiers

Air Conditioning and HVAC Services in Menomonee Falls, Wisconsin

Why Choose The Thielmann Group

Since 1929, our team has been the go-to choice for top-quality residential and commercial HVAC services in Menomonee Falls and beyond. Our NATE-certified technicians can service all brands, provide 24/7 emergency care, and more. Rest assured, we have you covered for all your HVAC needs! Plus, we offer upfront pricing, financing options, special deals, and a job well done.

Contact us online or call (262) 299-6197 to schedule the HVAC services you need.

Read Reviews by Our Customers

Recent Jobs and Reviews in Menomonee Falls, WI

Menomonee Falls, WI at a glance

Thielmann Heating, Cooling & Plumbing has completed 20 jobs in Menomonee Falls, WI in November 2026.

The most recent job was on November 14, 2026.

Thielmann Heating, Cooling & Plumbing has completed 334 jobs in Menomonee Falls, WI in the last 12 months.

Job Locations and Reviews

Performed scheduled seasonal heating maintenance under the recurring membership agreement, inspecting the furnace, PVC condensate and venting runs, flexible gas connection, shutoff valve, and plenum/ductwork. Visual inspection found no signs of frost, rust, or damage, and the unit's approved inspection tag and maintenance documentation were verified in place. Noted a small opening and powdery residue on the plenum panel for monitoring and follow-up.
Performed scheduled seasonal heating maintenance under the recurring membership agreement, inspecting the furnace, PVC condensate and venting runs, flexible gas connection, shutoff valve, and plenum/ductwork. Visual inspection found no signs of frost, rust, or damage, and the unit's approved inspection tag and maintenance documentation were verified in place. Noted a small opening and powdery residue on the plenum panel for monitoring and follow-up.
Todd H.
Todd H. Checked in
Performed scheduled seasonal heating maintenance under the recurring membership agreement, inspecting the furnace, PVC condensate and venting runs, flexible gas connection, shutoff valve, and plenum/ductwork. Visual inspection found no signs of frost, rust, or damage, and the unit's approved inspection tag and maintenance documentation were verified in place. Noted a small opening and powdery residue on the plenum panel for monitoring and follow-up.
Menomonee Falls, WI 53051
Performed a scheduled furnace tune-up on a Lennox unit, including electrical diagnostics with a True RMS clamp meter to verify component integrity and operating current. Measured component resistance (approximately 50.7 ohms) and confirmed motor/blower amperage draw of 2.16 A with no control voltage anomalies. Visually inspected the cabinet, blower assembly, wiring, and junction box, with no signs of frost, rust, or damage observed.
Performed a scheduled furnace tune-up on a Lennox unit, including electrical diagnostics with a True RMS clamp meter to verify component integrity and operating current. Measured component resistance (approximately 50.7 ohms) and confirmed motor/blower amperage draw of 2.16 A with no control voltage anomalies. Visually inspected the cabinet, blower assembly, wiring, and junction box, with no signs of frost, rust, or damage observed.
Todd H.
Todd H. Checked in
Performed a scheduled furnace tune-up on a Lennox unit, including electrical diagnostics with a True RMS clamp meter to verify component integrity and operating current. Measured component resistance (approximately 50.7 ohms) and confirmed motor/blower amperage draw of 2.16 A with no control voltage anomalies. Visually inspected the cabinet, blower assembly, wiring, and junction box, with no signs of frost, rust, or damage observed.
Menomonee Falls, WI 53051
Performed annual furnace tune-up, including inspection of the burner compartment, ignitor/flame sensor, and sight glass assembly, and verified manifold gas pressure with a digital manometer at 1.44 in. W.C. Noted heat-related staining and discoloration on the burner compartment insulation and recommend monitoring for continued deterioration, with system operation verified following reassembly.
Performed annual furnace tune-up, including inspection of the burner compartment, ignitor/flame sensor, and sight glass assembly, and verified manifold gas pressure with a digital manometer at 1.44 in. W.C. Noted heat-related staining and discoloration on the burner compartment insulation and recommend monitoring for continued deterioration, with system operation verified following reassembly.
Todd H.
Todd H. Checked in
Performed annual furnace tune-up, including inspection of the burner compartment, ignitor/flame sensor, and sight glass assembly, and verified manifold gas pressure with a digital manometer at 1.44 in. W.C. Noted heat-related staining and discoloration on the burner compartment insulation and recommend monitoring for continued deterioration, with system operation verified following reassembly.
MENOMONEE FALLS, WI 53051
Installed a new 50-gallon Bradford White electric tank water heater, connecting the hot and cold supply lines with copper piping, brass shutoff valves, and CPVC transitions. Installed a thermal expansion tank on the cold supply and completed the hardwired electrical connection in flexible conduit to the junction box. Verified the unit is leak-free and operating properly, and recorded the serial number for warranty registration.
Installed a new 50-gallon Bradford White electric tank water heater, connecting the hot and cold supply lines with copper piping, brass shutoff valves, and CPVC transitions. Installed a thermal expansion tank on the cold supply and completed the hardwired electrical connection in flexible conduit to the junction box. Verified the unit is leak-free and operating properly, and recorded the serial number for warranty registration.
Gabriel S.
Gabriel S. Checked in
Installed a new 50-gallon Bradford White electric tank water heater, connecting the hot and cold supply lines with copper piping, brass shutoff valves, and CPVC transitions. Installed a thermal expansion tank on the cold supply and completed the hardwired electrical connection in flexible conduit to the junction box. Verified the unit is leak-free and operating properly, and recorded the serial number for warranty registration.
Menomonee Falls, WI 53051
Responded to a leak complaint on an approximately 20-year-old furnace and found the condensate drain hose detached from the barbed elbow fitting at the cabinet, with rust staining and corrosion on the surrounding sheet metal and ductwork from prolonged moisture. Reattached the hose to the fitting, secured it with a clamp, and verified a proper condensate drain path with no further leakage.
Responded to a leak complaint on an approximately 20-year-old furnace and found the condensate drain hose detached from the barbed elbow fitting at the cabinet, with rust staining and corrosion on the surrounding sheet metal and ductwork from prolonged moisture. Reattached the hose to the fitting, secured it with a clamp, and verified a proper condensate drain path with no further leakage.
Nick K.
Nick K. Checked in
Responded to a leak complaint on an approximately 20-year-old furnace and found the condensate drain hose detached from the barbed elbow fitting at the cabinet, with rust staining and corrosion on the surrounding sheet metal and ductwork from prolonged moisture. Reattached the hose to the fitting, secured it with a clamp, and verified a proper condensate drain path with no further leakage.
Menomonee Falls, WI 53051
Menomonee Falls, WI - Responded to a no-heat call on a furnace over 10 years old and diagnosed a fault within the pressure switch circuit. Replaced the faulty pressure switch and verified wiring connections at the switch terminals were secure. Restored heating operation and confirmed proper safety circuit function and normal furnace cycling.
Nicholas H.
Nicholas H. Checked in
Responded to a no-heat call on a furnace over 10 years old and diagnosed a fault within the pressure switch circuit. Replaced the faulty pressure switch and verified wiring connections at the switch terminals were secure. Restored heating operation and confirmed proper safety circuit function and normal furnace cycling.
Menomonee Falls, WI 53051
Performed a second-opinion airflow evaluation on the furnace after the customer was told it wasn't receiving adequate air. Measured supply air temperature (approx. 117°F) and used a dual-port manometer to record static pressure readings (+0.29 in. W.C. supply, -0.49 in. W.C. return) to assess duct system and filter/coil restriction.
Performed a second-opinion airflow evaluation on the furnace after the customer was told it wasn't receiving adequate air. Measured supply air temperature (approx. 117°F) and used a dual-port manometer to record static pressure readings (+0.29 in. W.C. supply, -0.49 in. W.C. return) to assess duct system and filter/coil restriction.
George W.
George W. Checked in
Performed a second-opinion airflow evaluation on the furnace after the customer was told it wasn't receiving adequate air. Measured supply air temperature (approx. 117°F) and used a dual-port manometer to record static pressure readings (+0.29 in. W.C. supply, -0.49 in. W.C. return) to assess duct system and filter/coil restriction.
Menomonee Falls, WI 53051
Inspected and assessed an existing A.O. Smith electric water heater installed on a drain pan, noting rust streaking beneath the electrical access panel and down toward the lower fitting, indicating possible tank or fitting leakage and end-of-life condition. Evaluated supply piping, shutoff valves, flexible electrical conduit, and PVC discharge line, finding the upper connections clean with no visible leaks, and documented conditions to support a full water heater replacement estimate.
Inspected and assessed an existing A.O. Smith electric water heater installed on a drain pan, noting rust streaking beneath the electrical access panel and down toward the lower fitting, indicating possible tank or fitting leakage and end-of-life condition. Evaluated supply piping, shutoff valves, flexible electrical conduit, and PVC discharge line, finding the upper connections clean with no visible leaks, and documented conditions to support a full water heater replacement estimate.
Nick B.
Nick B. Checked in
Inspected and assessed an existing A.O. Smith electric water heater installed on a drain pan, noting rust streaking beneath the electrical access panel and down toward the lower fitting, indicating possible tank or fitting leakage and end-of-life condition. Evaluated supply piping, shutoff valves, flexible electrical conduit, and PVC discharge line, finding the upper connections clean with no visible leaks, and documented conditions to support a full water heater replacement estimate.
Menomonee Falls, WI 53051
Performed a scheduled furnace tune-up under the recurring maintenance agreement, inspecting the cabinet interior, blower motor, and electrical connections and measuring motor amperage with a clamp meter to verify operation within normal range. Noted surface rust on a control component mounted within the furnace enclosure and checked the condensate PVC piping, flexible duct connection, and wiring harness for secure fit and proper routing.
Performed a scheduled furnace tune-up under the recurring maintenance agreement, inspecting the cabinet interior, blower motor, and electrical connections and measuring motor amperage with a clamp meter to verify operation within normal range. Noted surface rust on a control component mounted within the furnace enclosure and checked the condensate PVC piping, flexible duct connection, and wiring harness for secure fit and proper routing.
Nick K.
Nick K. Checked in
Performed a scheduled furnace tune-up under the recurring maintenance agreement, inspecting the cabinet interior, blower motor, and electrical connections and measuring motor amperage with a clamp meter to verify operation within normal range. Noted surface rust on a control component mounted within the furnace enclosure and checked the condensate PVC piping, flexible duct connection, and wiring harness for secure fit and proper routing.
Menomonee Falls, WI 53051
Performed a prepaid furnace tune-up, including inspection of the heat exchanger, gas valve, blower motor, and control wiring, and a filter check that found the pleated filter deformed and the filter-compartment insulation torn. Conducted a combustion analysis on natural gas with a flue gas analyzer, recording a stack temperature of 213.2°F, 14.4% O2, 55 ppm CO (176 ppm air-free), 3.69% CO2, 80.2% efficiency, and 195.2% excess air. These readings indicate excessive excess air and low CO2, warranting further evaluation of combustion and airflow.
Performed a prepaid furnace tune-up, including inspection of the heat exchanger, gas valve, blower motor, and control wiring, and a filter check that found the pleated filter deformed and the filter-compartment insulation torn. Conducted a combustion analysis on natural gas with a flue gas analyzer, recording a stack temperature of 213.2°F, 14.4% O2, 55 ppm CO (176 ppm air-free), 3.69% CO2, 80.2% efficiency, and 195.2% excess air. These readings indicate excessive excess air and low CO2, warranting further evaluation of combustion and airflow.
Nick K.
Nick K. Checked in
Performed a prepaid furnace tune-up, including inspection of the heat exchanger, gas valve, blower motor, and control wiring, and a filter check that found the pleated filter deformed and the filter-compartment insulation torn. Conducted a combustion analysis on natural gas with a flue gas analyzer, recording a stack temperature of 213.2°F, 14.4% O2, 55 ppm CO (176 ppm air-free), 3.69% CO2, 80.2% efficiency, and 195.2% excess air. These readings indicate excessive excess air and low CO2, warranting further evaluation of combustion and airflow.
Menomonee Falls, WI 53051
Performed an on-site plumbing estimate for supply and drain connections to a new vanity and sink. Inspected the existing under-sink PVC drain assembly with P-trap and garbage disposal tie-in, along with the chrome angle-stop valves and braided supply lines, noting rust and corrosion on the right-hand supply pipe below its stop valve and water staining on the cabinet back wall that indicate a past or active leak. Also assessed the basement supply routing of galvanized steel and CPVC piping with shutoff valves to evaluate access and tie-in points for the new fixture connections.
Performed an on-site plumbing estimate for supply and drain connections to a new vanity and sink. Inspected the existing under-sink PVC drain assembly with P-trap and garbage disposal tie-in, along with the chrome angle-stop valves and braided supply lines, noting rust and corrosion on the right-hand supply pipe below its stop valve and water staining on the cabinet back wall that indicate a past or active leak. Also assessed the basement supply routing of galvanized steel and CPVC piping with shutoff valves to evaluate access and tie-in points for the new fixture connections.
Nick B.
Nick B. Checked in
Performed an on-site plumbing estimate for supply and drain connections to a new vanity and sink. Inspected the existing under-sink PVC drain assembly with P-trap and garbage disposal tie-in, along with the chrome angle-stop valves and braided supply lines, noting rust and corrosion on the right-hand supply pipe below its stop valve and water staining on the cabinet back wall that indicate a past or active leak. Also assessed the basement supply routing of galvanized steel and CPVC piping with shutoff valves to evaluate access and tie-in points for the new fixture connections.
Menomonee Falls, WI 53051
Performed a seasonal heating tune-up on the gas furnace under the recurring maintenance agreement. Removed the front panel and inspected the burner/manifold assembly, gas valve, inducer motor and blower housing, pressure switch, and wiring harness connections, noting light surface rust on the burner bracket edges and dust accumulation on internal components. Conducted a thermal imaging scan of the equipment and surrounding ductwork and piping to verify heat distribution and identify abnormal hot spots.
Performed a seasonal heating tune-up on the gas furnace under the recurring maintenance agreement. Removed the front panel and inspected the burner/manifold assembly, gas valve, inducer motor and blower housing, pressure switch, and wiring harness connections, noting light surface rust on the burner bracket edges and dust accumulation on internal components. Conducted a thermal imaging scan of the equipment and surrounding ductwork and piping to verify heat distribution and identify abnormal hot spots.
Jon Y.
Jon Y. Checked in
Performed a seasonal heating tune-up on the gas furnace under the recurring maintenance agreement. Removed the front panel and inspected the burner/manifold assembly, gas valve, inducer motor and blower housing, pressure switch, and wiring harness connections, noting light surface rust on the burner bracket edges and dust accumulation on internal components. Conducted a thermal imaging scan of the equipment and surrounding ductwork and piping to verify heat distribution and identify abnormal hot spots.
Menomonee Falls, WI 53051
Performed a maintenance agreement visit on a natural gas furnace, including combustion analysis with a flue gas analyzer that recorded a stack temperature of 108.9°F, 6.4% O₂, 8.20% CO₂, 24 ppm CO (35 ppm air-free), 39.2% excess air, and 93.5% efficiency, indicating safe and efficient combustion. Inspected the gas piping and fittings at the unit, finding the joints sealed and free of visible damage, and verified a return air temperature of 68.1°F with a pocket thermometer on the air handler cabinet.
Performed a maintenance agreement visit on a natural gas furnace, including combustion analysis with a flue gas analyzer that recorded a stack temperature of 108.9°F, 6.4% O₂, 8.20% CO₂, 24 ppm CO (35 ppm air-free), 39.2% excess air, and 93.5% efficiency, indicating safe and efficient combustion. Inspected the gas piping and fittings at the unit, finding the joints sealed and free of visible damage, and verified a return air temperature of 68.1°F with a pocket thermometer on the air handler cabinet.
Nick K.
Nick K. Checked in
Performed a maintenance agreement visit on a natural gas furnace, including combustion analysis with a flue gas analyzer that recorded a stack temperature of 108.9°F, 6.4% O₂, 8.20% CO₂, 24 ppm CO (35 ppm air-free), 39.2% excess air, and 93.5% efficiency, indicating safe and efficient combustion. Inspected the gas piping and fittings at the unit, finding the joints sealed and free of visible damage, and verified a return air temperature of 68.1°F with a pocket thermometer on the air handler cabinet.
MENOMONEE FALLS, WI 53051
Diagnosed a non-functioning Kohler single-handle tub/shower valve and a slow-draining sink. Removed the handle and escutcheon plate to expose the valve cartridge and stem, inspected the cartridge assembly and mounting plate, and found the wall opening around the valve chipped and deteriorated, with water running from the tub spout. Evaluated the cartridge and surrounding wall condition to determine the cause of the handle failure and documented findings for repair.
Diagnosed a non-functioning Kohler single-handle tub/shower valve and a slow-draining sink. Removed the handle and escutcheon plate to expose the valve cartridge and stem, inspected the cartridge assembly and mounting plate, and found the wall opening around the valve chipped and deteriorated, with water running from the tub spout. Evaluated the cartridge and surrounding wall condition to determine the cause of the handle failure and documented findings for repair.
Kyle L.
Kyle L. Checked in
Diagnosed a non-functioning Kohler single-handle tub/shower valve and a slow-draining sink. Removed the handle and escutcheon plate to expose the valve cartridge and stem, inspected the cartridge assembly and mounting plate, and found the wall opening around the valve chipped and deteriorated, with water running from the tub spout. Evaluated the cartridge and surrounding wall condition to determine the cause of the handle failure and documented findings for repair.
Menomonee Falls, WI 53051
Evaluated the existing basement sump system, which includes a single sump basin with a PVC discharge line, and assessed the installation of a secondary sump pump and a battery backup system. Documented the pit, discharge routing, and surrounding conditions, noting sediment buildup around the basin cover and moisture staining on the adjacent block wall.
Evaluated the existing basement sump system, which includes a single sump basin with a PVC discharge line, and assessed the installation of a secondary sump pump and a battery backup system. Documented the pit, discharge routing, and surrounding conditions, noting sediment buildup around the basin cover and moisture staining on the adjacent block wall.
Nick B.
Nick B. Checked in
Evaluated the existing basement sump system, which includes a single sump basin with a PVC discharge line, and assessed the installation of a secondary sump pump and a battery backup system. Documented the pit, discharge routing, and surrounding conditions, noting sediment buildup around the basin cover and moisture staining on the adjacent block wall.
Menomonee Falls, WI 53051
Installed a complete HVAC system consisting of a new furnace, air conditioning system, and humidifier under permit. Set the outdoor condenser on a level pad with a fused disconnect, flexible conduit whip, and insulated copper refrigerant lines routed to the structure. Completed the attic-side connections, including secured control wiring and ductwork, and verified system operation.
Installed a complete HVAC system consisting of a new furnace, air conditioning system, and humidifier under permit. Set the outdoor condenser on a level pad with a fused disconnect, flexible conduit whip, and insulated copper refrigerant lines routed to the structure. Completed the attic-side connections, including secured control wiring and ductwork, and verified system operation.
Hayden L.
Hayden L. Checked in
Installed a complete HVAC system consisting of a new furnace, air conditioning system, and humidifier under permit. Set the outdoor condenser on a level pad with a fused disconnect, flexible conduit whip, and insulated copper refrigerant lines routed to the structure. Completed the attic-side connections, including secured control wiring and ductwork, and verified system operation.
MENOMONEE FALLS, WI 53051
Responded to a no-heat call on a Carrier 80% two-stage furnace (model 58TUA060-12). Inspected the burner compartment, inducer assembly, low- and high-fire pressure switches, gas valve, and control wiring, and confirmed a pilot/burner flame was present with no visible corrosion, ice, or component damage. The furnace was left with its access panels in place, and the findings and equipment age were documented.
Responded to a no-heat call on a Carrier 80% two-stage furnace (model 58TUA060-12). Inspected the burner compartment, inducer assembly, low- and high-fire pressure switches, gas valve, and control wiring, and confirmed a pilot/burner flame was present with no visible corrosion, ice, or component damage. The furnace was left with its access panels in place, and the findings and equipment age were documented.
Nicholas H.
Nicholas H. Checked in
Responded to a no-heat call on a Carrier 80% two-stage furnace (model 58TUA060-12). Inspected the burner compartment, inducer assembly, low- and high-fire pressure switches, gas valve, and control wiring, and confirmed a pilot/burner flame was present with no visible corrosion, ice, or component damage. The furnace was left with its access panels in place, and the findings and equipment age were documented.
Menomonee Falls, WI 53051
Performed a furnace tune-up, including electrical testing of the blower motor circuit with a true-RMS multimeter (resistance measured 53.1 Ω) and a visual inspection of the furnace cabinet, wiring, and status-code label. Inspected the PVC condensate/drain piping, flue/vent connections, and surrounding ductwork, noting dust buildup but no visible damage, rust, leaks, or cracks, and verified the unit was in satisfactory operating condition.
Performed a furnace tune-up, including electrical testing of the blower motor circuit with a true-RMS multimeter (resistance measured 53.1 Ω) and a visual inspection of the furnace cabinet, wiring, and status-code label. Inspected the PVC condensate/drain piping, flue/vent connections, and surrounding ductwork, noting dust buildup but no visible damage, rust, leaks, or cracks, and verified the unit was in satisfactory operating condition.
Todd H.
Todd H. Checked in
Performed a furnace tune-up, including electrical testing of the blower motor circuit with a true-RMS multimeter (resistance measured 53.1 Ω) and a visual inspection of the furnace cabinet, wiring, and status-code label. Inspected the PVC condensate/drain piping, flue/vent connections, and surrounding ductwork, noting dust buildup but no visible damage, rust, leaks, or cracks, and verified the unit was in satisfactory operating condition.
Menomonee Falls, WI 53051
Performed a furnace tune-up and verified system performance using digital instrumentation. Measured static pressure with a Testo 510i manometer, recording 2.93 inH2O, and checked supply register discharge air temperature at 115.1°F with a pocket thermometer to confirm proper heating operation.
Performed a furnace tune-up and verified system performance using digital instrumentation. Measured static pressure with a Testo 510i manometer, recording 2.93 inH2O, and checked supply register discharge air temperature at 115.1°F with a pocket thermometer to confirm proper heating operation.
Todd H.
Todd H. Checked in
Performed a furnace tune-up and verified system performance using digital instrumentation. Measured static pressure with a Testo 510i manometer, recording 2.93 inH2O, and checked supply register discharge air temperature at 115.1°F with a pocket thermometer to confirm proper heating operation.
MENOMONEE FALLS, WI 53051
Installed a new Lennox gas furnace under permit, complete with new galvanized supply plenum and ductwork connections, PVC combustion venting, condensate drain with pump, and a gas line with shutoff valve. A licensed electrician completed the line-voltage wiring and disconnect, and a new controller was mounted on the ductwork. System was set up on raised blocks, and all connections were secured and left clean.
Installed a new Lennox gas furnace under permit, complete with new galvanized supply plenum and ductwork connections, PVC combustion venting, condensate drain with pump, and a gas line with shutoff valve. A licensed electrician completed the line-voltage wiring and disconnect, and a new controller was mounted on the ductwork. System was set up on raised blocks, and all connections were secured and left clean.
Branden B.
Branden B. Checked in
Installed a new Lennox gas furnace under permit, complete with new galvanized supply plenum and ductwork connections, PVC combustion venting, condensate drain with pump, and a gas line with shutoff valve. A licensed electrician completed the line-voltage wiring and disconnect, and a new controller was mounted on the ductwork. System was set up on raised blocks, and all connections were secured and left clean.
Menomonee Falls, WI 53051

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Thielmann Heating, Cooling & Plumbing Difference

Fully Licensed & Insured

Our experts have the expertise and training to deliver the highest quality services every time.

Trusted Since 1929

We have served Southeastern Wisconsin for nearly a century, so we understand the needs of our community.

Financing Available

We offer various options from financing partners to help you meet your specific needs and budget.

5-Star Customer Service

Thielmann Heating, Cooling & Plumbing promises five-star customer service with every interaction.

Committed to Excellence

We complete jobs quickly without compromising our commitment to excellence.

Satisfaction Guarantee

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Fully Licensed & Insured

Our experts have the expertise and training to deliver the highest quality services every time.

Trusted Since 1929

We have served Southeastern Wisconsin for nearly a century, so we understand the needs of our community.

Financing Available

We offer various options from financing partners to help you meet your specific needs and budget.

5-Star Customer Service

Thielmann Heating, Cooling & Plumbing promises five-star customer service with every interaction.

Committed to Excellence

We complete jobs quickly without compromising our commitment to excellence.

Satisfaction Guarantee

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Review Image
Our Reviews

See What Your Neighbors Are Saying

I liked my experience with them. The guys I spoke with prior to doing the work, the estimation phase , and the ones I spoke with after the work was completed had enough knowledge and suggestion to answer all my questions. I’m pleased with the job…

De'Angelo T.

De'Angelo T.

Excellent team from start to finish. They were all very respectful of our property, as they promptly and professionally went about their task of installing a new air conditioner system. The system works very well, so far. It is also much quieter than the previous 40+…

Jerry W.

Jerry W.

Thielmann did a tremendous job replacing our Carrier furnace. They worked with us to make sure we were able to get the right product and even worked with Carrier on the issues we were seeing on our old furnace as it was failing sooner than it…

J. K.

J. K.

I've been using Thielmann Group for all my heating and air conditioning since I built my house 23 years ago. They have been great in emergency service and regular maintenance service. On time and very friendly staff. Would, and have, recommend them to anyone!

Paul K.

Paul K.

I have used Thielmann for both installation of a new furnace + A/C recently, but also an install of a ductless mini-split unit six years ago. I fully trust their brands and recommendations. I can't say enough of about this company. Every single person from administrative…

Christin C.

Christin C.